Feature:-
ZT-3200 | HPLC - Isocrated System | High Pressure Solvent Delivery Pump Multi Wavelength UV-Detector Sample Inject Valve - (Rheodyne 7725 I) Lc Column (Usa) - {C18(4.6 X 250)mm} Workstation Software |
Spectral Range | 7800 to 350 cm-1 |
Resolution | Better than 0.85cm-1 |
Wave Number | ±0.01cm-1 |
Scanning Speed | 5-step adjustable for different applications |
Signal to noise ratio | better than 15,000:1 (RMS value, at 2100cm-1, resolution: 4cm-1,detector: DTGS, 1 minute data collection) |
Beam splitter | Ge coated KBr |
Infrared Source | Air-cooled, high efficiency Reflex |
Detector | DTGS |
Data system | Compatible computer |
Software | FT-IR software contains all routines needed for basic spectrometer operations, including library search, quantitation and=20 spectrum export |
IR Library | 11 IR libraries include |
Block Capacity | 61 x 0.2 ml or 36 x 0.5 ml |
Temperature Range | 4°C to 99°C |
Max. Heating Rate | <2.5 °C/s |
Max. Cooling Rate | <2.5 °C/s |
Temperature display accuracy | 0.1°C |
Accuracy | < + 2.5°C/s |
Temperature Fluctuation | < + 0.1°C |
Uniformity | 95°C h< + 0.5°C (20 seconds later) |
20°C ~ 72°C h < + 0.3°C (20 seconds later) | |
Max. Program unit | 9 |
Max. Cycle Step | 9 |
Max. Cycle No. | 99 |
Max. constant temperature | 59m59s |
Stores Program No. | 9h59m |
Stored Program No. | 100 |
Dimension | 370 mm (L) x 249 mm (W) x 180 mm (H) |
Weight | 5 Kg. |
Wavelength Range | 190-1100 nm |
Spectral Bandwidth | 1 nm |
Working Mode | T,A,C,E |
Optical System | Double beam |
Scanning Speed | Fast / Medium / Slow |
Photometric Range | -0.3 - 3.5 A, 0 to 220 %T |
Wavelength Accuracy | +0.3 nm |
Wavelength Reproducibility | < 0.10 nm |
Photometric Accuracy | + 0.3% T (0-100% T) +0.002 A (0-0.1 A) |
Photometric Reproducibility | < 0.15 % T |
Stray Light | < 0.1% T (Nal. 220nm, NaNO2 340 nm) |
Baseline Flatness | + 0.002 A |
Stability | < 0.001A/h (at 500 nm, after warming up) |
Noise | +0.001A (at 500 nm, after warming up) |
Detector | Dual Silicon Photodiode |
Display | 6 inches high light blue LCD |
Power | AC:220V + 10%, 50 Hz. |
Dimensions | 630 x 470 x 210 mm |
Weight | 26 Kg |
Glass Cells | 16 No. |
Quartz Cells | 4 Nos. |
Fuse | 3 Nos. |
Instrument Cover | 1 No. |
Software CD | 1 No. |
RS 232 Cable | 1 No. |
Operation Manual | 1 No. |
Â
Wavelength Range | 190-1100 nm (1200 Lines/mm grating) |
Mode | Basic/Quantitative/Wavelength Scan/DNA Protein Test/Kinetics |
Scanning Speed | Fast / Medium / Slow |
Wavelength Accuracy | +0.1 nm |
Bandwidth | 0.5, 1,2,4,5 |
Wavelength Reproducibility | 0.1 nm |
Photometric Display Range | 0-200 % T, -0.3 - 3.0 A, 0-9999 C |
Photometric Accuracy | + 0.3 % T |
Photometric Repeatability | + 0.2 % T |
Stability | 0.001A/h @ 500 nm |
Baseline Flatness | + 0.001 A |
Noise | +0.001A |
Stray Light | < 0.05% T @ 220nm, 360 nm) |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | Graphic LCD (320*240 Dots) |
Lamps | Deuterium Lamp & Tungsten Halogen Lamp |
Detector | Silicon Photodiode |
Dimensions(L*W*H) | 630 x 430 x 206 mm |
Net Weight | 26 Kg |
Wavelength Range | 190-1100 nm |
Spectral Bandwidth | 1 nm |
Working Mode | T,A,C,E |
Optical System | Double beam |
Scanning Speed | Fast / Medium / Slow |
Photometric Range | -0.3 - 3.5 A, 0 to 220 %T |
Wavelength Accuracy | +0.3 nm |
Wavelength Reproducibility | < 0.10 nm |
Photometric Accuracy | + 0.3% T (0-100% T) +0.002 A (0-0.1 A) |
Photometric Reproducibility | < 0.15 % T |
Stray Light | < 0.1% T (Nal. 220nm, NaNO2 340 nm) |
Baseline Flatness | + 0.002 A |
Stability | < 0.001A/h (at 500 nm, after warming up) |
Noise | +0.001A (at 500 nm, after warming up) |
Detector | Dual Silicon Photodiode |
Display | 6 inches high light blue LCD |
Power | AC:220V + 10%, 50 Hz. |
Dimensions | 630 x 470 x 210 mm |
Weight | 26 Kg |
Glass Cells | 16 No. |
Quartz Cells | 4 Nos. |
Fuse | 3 Nos. |
Instrument Cover | 1 No. |
Software CD | 1 No. |
RS 232 Cable | 1 No. |
Operation Manual | 1 No. |
Wavelength Range | 190-1100 nm |
Spectral Bandwidth | 1 nm |
Working Mode | T,A,C,E |
Optical System | Double beam |
Scanning Speed | Fast / Medium / Slow |
Photometric Range | -0.3 - 3.5 A, 0 to 220 %T |
Wavelength Accuracy | +0.3 nm |
Wavelength Reproducibility | < 0.10 nm |
Photometric Accuracy | + 0.3% T (0-100% T) +0.002 A (0-0.1 A) |
Photometric Reproducibility | < 0.15 % T |
Stray Light | < 0.1% T (Nal. 220nm, NaNO2 340 nm) |
Baseline Flatness | + 0.002 A |
Stability | < 0.001A/h (at 500 nm, after warming up) |
Noise | +0.001A (at 500 nm, after warming up) |
Detector | Dual Silicon Photodiode |
Display | 6 inches high light blue LCD |
Power | AC:220V + 10%, 50 Hz. |
Dimensions | 630 x 470 x 210 mm |
Weight | 26 Kg |
Glass Cells | 16 No. |
Quartz Cells | 4 Nos. |
Fuse | 3 Nos. |
Instrument Cover | 1 No. |
Software CD | 1 No. |
RS 232 Cable | 1 No. |
Operation Manual | 1 No. |
Wavelength Range | 190 ~ 1100 nm |
Wavelength Accuracy | .05 nm |
Wavelength Reproducibility | 0.2 nm |
Spectral bandwidth | 1 nm |
Photometric Accuracy | 0.3% |
Photometric Reproducibility | 0.15 % |
Stray Light | 0.05 % |
Stability | < 0.001A/h |
Baseline | < + 0.002A |
Noise | 0.15 % for 100 % =3D 0.01% for 0 % |
Photometric range |
Trans 0 ~ 200.0 % Abs -0.301 ~ 3.000 A Conc . 0 ~ 99999 Factor 0 ~ 99999 |
Display | 5.6 inch 800×480 pixel touch-screen graphic LCD |
Lamp | Prealigned long lifetime Shimadzu deuterium lamp. Fuji long lifetime halogen-tungsten lamp. |
Optical System | C-T configuration diffraction grating monochromator, double beam ratio 20 recording system. |
Interface | RS232 serial interface (with RS232C-USB2.0 converter suit) |
Scanning Function | Ok |
Power Supply | 100v-240v (50-60)±Hz |
Dimensions | 490×490×210 mm Packing Dimensions 620×620×380 mm |
Weight | N.W.:20Kg G.W.:25Kg |
Wavelength Range | 190-1100 nm Czerny Turner |
Spectral Bandwidth | 1 nm |
Working Mode | Basic/Quantative/Wavelength Scan/DNA Protein Test/Kinestics=20 (T,A,C) |
Optical System | Double beam |
Scanning Speed | Fast / Medium / Slow |
Photometric Range | -0.3 - 3.5 A, 0 to 220 %T |
Wavelength Accuracy | +0.3 nm |
Wavelength Reproducibility | < 0.10 nm |
Photometric Accuracy | + 0.3% T (0-100% T) +0.002 A (0-0.1 A) |
Photometric Reproducibility | < 0.15 % T |
Stray Light | < 0.1% T (Nal. 220nm, NaNO2 340 nm) |
Baseline Flatness | + 0.002 A |
Stability | < 0.001A/h (at 500 nm, after warming up) |
Noise | +0.001A (at 500 nm, after warming up) |
Detector | Dual Silicon Photodiode |
Display | 6 inches high light blue LCD |
Power | AC:220V + 10%, 50 Hz. |
Dimensions | 630 x 470 x 210 mm |
Weight | 26 Kg |
Glass Cells | 16 No. |
Quartz Cells | 4 Nos. |
Fuse | 3 Nos. |
Instrument Cover | 1 No. |
Software CD | 1 No. |
RS 232 Cable | 1 No. |
Operation Manual | 1 No. |
Optical System | Single Beam, Grating 1200 lines/mm |
Wavelength Range | 200-1000nm |
Band Width | 1 nm |
Wavelength Accuracy | ±0.5 nm |
Wavelength Repeatability | +0.1nm |
Wavelength Setting | Automatic |
Photometric Accuracy | ±0.1 %T |
Photometric Repeatability | +0.3 %T |
Photometric Display Range | -0.3-3.0A,0-200%T, 0-9999C |
Stability | +0.002A/h @ 500nm |
Stray Light | ≤0.3%T @220nm, 360nm |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | Deuterium Lamp & Tungsten Halogen Lamp |
Detector | Silicon Photodiode |
Power Requirement | AC220V/50 Hz |
Optical System | Single Beam, Grating 1200 lines/mm |
Wavelength Range | 200-1000nm |
Band Width | 1 nm |
Wavelength Accuracy | ±0.5 nm |
Wavelength Repeatability | +0.1nm |
Wavelength Setting | Automatic |
Photometric Accuracy | ±0.1 %T |
Photometric Repeatability | +0.3 %T |
Photometric Display Range | -0.3-3.0A,0-200%T, 0-9999C |
Stability | +0.002A/h @ 500nm |
Stray Light | ≤0.3%T @220nm, 360nm |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | Deuterium Lamp & Tungsten Halogen Lamp |
Detector | Silicon Photodiode |
Power Requirement | AC220V/50 Hz |
Optical Design | Sinle-beam, grating-based, dual detectors |
Display | 6 inches 128×64 dots backlight digital LCD |
Data Interface | RS232(printout or communication) |
Printer | Thermal graphics printer or universal Printer |
Languages | Software, printout and operators manual: English |
Software |
Photometric measurement (Absorbance ration, Absorbance difference) Spectral measurement (Survey scan) Quantitative measurement (Standard curve, Multi wavelength) Kinetic measurement |
Keyboard | Membrane Key Pad |
Cell Holder | 4-position automatic cuvette rack for 4 cuvettes - 10 MM. |
Spectral Bandwidth | 2 nm |
Optical Design | Split-beam,grating-based,dual detectors |
Lamp Source | Prealigned deuterium lamp with 3000 hours lifetime, Halogen-Tungsten Lamp with 10000 hours lifetime |
Wavelength Range | 190-1100nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Reproducibility | ≤0.2nm |
Photometric range |
0-999.9%T -3A-3A 0-9999C |
Photometric Accuracy |
±0.3%(t) (0-100%t) 0.002A (0-0.5A) 0.004A(0.5-1A) |
Photometric Reproducibility |
≤0.15%(t) (0-100%t) 0.001A(0-0.5A) 0.002A(0.5-1A) |
Photometric Readout | Absorbance,Transmittance,Concentration Energy |
Noise | ±0.001A |
Drift | 0.001A/h |
Stray Light | ≤0.05%(t) (220nm, NaI) |
Power Requirements | Automatically adapted input power 100-240volts |
Warranty | 1 Year Warranty. |
Photometric Range | % T:0 to 100%, Abs.:0 to 1.999 Conc.:0 to 1999, K-Factor:0 to 1999 |
Accuracy | +0.005 Abs at 1.0 Abs +0.010 Abs at 1.0 Abs |
Stray Light | Less thn 0.1% Abs at 320 nm |
Readability | +1 Count |
Data Readout | Single Line LCD display |
Key Board | 4 Keys, Soft touch membrane type |
Painter Interface | Printer interface for any printer |
Serial Interface | RS 232C interface |
Light Source | a) Tungsten Halogen Lamp b) Deuterium Lamp (D2) |
Detector | Wide range Silicon Photodiode |
Optics | Complete mirror optics with resolution 1200 grooves/mm grating |
Sample Holder | 4 position adjustable sample holder |
Power | 230V + 10%, 50 Hz. AC |
Dimensions | 420 x 350 x 240 mm (lxbxh) Approx. |
Weight | 10 Kg (Approx.) |
Wavelength | 195 to 1000nm |
Spectral Bandwidth | 2 nm |
Accuracy | + 0.5 nm |
Repeatability | + 0.3 nm |
Resolution | 0.1 nm |
Range 195 to 1000 nm with facility for automatic concentration, % Transmission, Absorbance & K Factor measurement. It has sample holder with 4 position selector control for 10 mm path length cuvettes. Facility has been provided for interface with any printer (RST 232C). Set of 2 quartz and 4 glass cuvettes is provided. SOFTWARE INCLUDED (Imported)
Microprocessor Viscometer has the advantage of high accuracy, stable digital display, easy to operate and good anti–interference. It is widely used in the measurement of viscosity of various kinds of fluids such as grease, paints, food, medicine, adhesive and cosmetic etc., it can also be used to determine the viscosity resistance and absolute viscosity of the liquids.
1. Its with led display.
2. Measurement range is 10-1 x 105 mpa.s with 4 spindles, 6/12/30/60 rotor speed (rpm), + 5 % newtonian fluid.
3. Provided with RS232c interface.
Optical System | Single Beam, Grating 1200 lines/mm |
Wavelength Range | 200-1000nm |
Band Width | 1 nm |
Wavelength Accuracy | ±0.5 nm |
Wavelength Repeatability | +0.1nm |
Wavelength Setting | Automatic |
Photometric Accuracy | ±0.1 %T |
Photometric Repeatability | +0.3 %T |
Photometric Display Range | -0.3-3.0A,0-200%T, 0-9999C |
Stability | +0.002A/h @ 500nm |
Stray Light | ≤0.3%T @220nm, 360nm |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | Deuterium Lamp & Tungsten Halogen Lamp |
Detector | Silicon Photodiode |
Power Requirement | AC220V/50 Hz |
Model |
ZT-10 Deluxe pH Meter |
ZT-11 Digital pH Meter |
ZA-14 Portable Model |
|
Display | 3 1/2 digit LED | 3 1/2 digit LED | 3 1/2 digit LCD | |
Range |
pH | 0 to 14.00 | 0 to 14.00 | 0 to 14.00 |
mV | 0 to + 1999 | 0 to + 1999 | - | |
Resolution |
pH | 0.01 | 0.01 | 0.01 |
mV | 1 | 1 | - | |
Accuracy |
pH | +0.01 | +0.01 | +0.01 |
mV | +1 | +1 | - | |
Temperature | Auto 0 to 100 | - | - | |
Compensation | Manual 0 to 100 | Manual 0 to 100 | Manual 0 to 100 | |
Slope Correction | 80 to 120% | 80 to 120% | 80 to 120% | |
Power | 230V + 10% | 230V + 10% | 1 x 9V Battery | |
Dimensions | 76 x 275 x 175 | 6 x 275 x 175 | 85 x 28 x 165 |
The Bio-Chemistry Analyzer is mainly used for the quantitative analysis of the clinical bio-chemical items; it applies the lamber- beer law: A=kbc=lg(i0/i).
Among them:a: absorbency, k: aspirated index, b: liquid layer’s thickness, c: solution’s consistency, i0: incident light’s strength, i: transmit light’s strength.
According to the above formulas, under the condition of the certain liquid layer’s thickness and incident light’s strength, as long as test the strength of transmit light which goes through the liquid, so we can calculate the consistency of the solution.
Technical parameters condition for operation
10°C -35°C
20 - 90 %.
85 -264V
Conserved Transportation Condition:
0°C-40°C
10% -90 %.
kinetic.
End-point, linearity, plus time, non linearity plus time, absorbency, sample blank, multi-standard, velocity, calculation, two-point, double wavelength etc.
7 wavelengths optic system avoiding outer disturbance.
340-700nm
quality control for all tests, statistic and print quality control parameters automatically with QC curves. Every test can do high medium low three groups quality control.
add or delete test items easily according to the condition. Modify the test parameters. Display dynamic curves at real time.
The print content includes comprehensive hospital's name and sample' materials. Dormant automatically for the lamp to prolong it's life span/input
8 standard curves at most in testing with multi standard method.
≥200filter
340. 380. 405. 505. 546. 578. 620nm, 1 empty position wavelength
±2NM.
-0. 2 - 2. 3 abs.
quartz .
32ULL
quartz-halogen lamp, 6V 10W.
10mm.
240×128 dots graphic LCD.
RS-232 serial.
33cm in length*35. 5cm in width*12. 59cm in height
Model | LT - 114 (Digital) |
Std. Glass Filter | 8 |
Mini Volume | 1 ml. |
Display | 3 Digit, Bright Red 7 Segment LED |
Range | 400-700 nm |
Output | OD: (0 to 1.99), %T: 0 to 199 |
Resolution | OD : 0.01, %T : 1% |
Accuracy | 0.5% FSI |
Detector | Selenium Photocell/Photodiode |
Light Source | 6.8v, 300mA |
Power | 230V + 10%, 50 Hz. AC |
Model | LT12 Digital Model | LT13 Digital Model |
Std. Glass Filter | 8 | 5 |
Mini Volume | 1 ml. | 1 ml. |
2 1/2 Digit LED | 2 1/2 Digit LED | |
Range | 400-700 nm | 400-700 nm |
Output | OD (0 to 1.99) | OD (0 to 1.99) |
Resolution | OD : 0.01 | OD : 0.01 |
Accuracy | 0.5% FSI | 0.5% FSI |
Detector | Selenium Photocell | Selenium Photocell |
Light Source | 6.8v, 300mA | 6.8v, 300mA |
Power | 230v + 10% | 230v + 10% |
Accessories | Test Tube set of 5, Spare Lamp, Dust Cover, Manual |
|
Filters | 8 Filters - 400, 420, 480, 500, 520, 540, 620 , 680 nm 5 Filters - 420, 480, 540, 620, 680 nm |
Microprocessor Based pH Meter
Grafical Display
Range:
Range | 0.00-14.00pH |
Resolution | 0.01pH |
Calibration | 3 Point Automatic Calibration |
Display | Graphical |
Power Supply | 230V AC +10% 50Hz |